Features

  •  Sequence function to do high Efficient load simulations
  • Flexible configuration with mainframes and plug-in modules
  • Multiple independent load inputs up to 8 channels in a mainframe
  • Parallel connection of inputs for increased load capacity
  •  Parallel connection of inputs for static and dynamic tests
  •  OPP/OCP/OVP/OTP protections
  • External channel control/monitoring via an analog control connector
  • Multi-Interface USB Device / Host, RS-232C, and GPIB (Optional)
SKU: PEL-2000A Categories: , Tag:

Product Description

****IMPORTANT!!!! PEL-2000 Series discontinued solution by using PEL-2000A Series****

 

Satisfy All Your High Speed Load Simulation Needs

The PEL-2004A and PEL-2002A are multiple channel, programmable DC electronic loads with a modularized structure. The PEL-2000A Series is designed to meet the continuing shift toward high speed operation in today’s semiconductor market. As the power supply units, DC-DC converters, and batteries that drive semiconductor circuits to follow this shift, power supply design, quality inspection, and characteristic certification using high-speed performance loads have become necessary. The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users’ requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.For higher load capacities, mainframes can be linked together in parallel with standard MIL 20-pin connectors. A maximum of 5 mainframes, including one master and 4 slaves can be chained together to create a total load capacity of 7kW for high current and high power applications. Using 4 dual channel load modules, the PEL-2004A is able to test 8 power supply outputs simultaneously. The Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently under the control of one clock. This is one of the most powerful features of the PEL-2000A ASeries as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed up to 25 s per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes. Most remarkably, multiple load channels can be connected in parallel to run Dynamic tests synchronously under a single clock. This Parallel Dynamic functionality gives the flexibility to perform dynamic tests for a high-power power supply without the need of another high-power load.

The PEL-2000A Series includes a number of protection modes: Over Current Protection (OCP), Over Voltage Protection (OVP), Over Power Protection (OPP), Reverse Voltage Protection (RVP), and Under Voltage Protection(UVP). The protection modes are useful to protect both the load modules and the DUT(s). A buzzer can be set when a protection setting has been tripped. When a protection mode has been tripped, the load unit will display an alarm and stop sinking current/voltage. When a load unit is operating in CR or CV mode, the unit may need Over Current Protection to prevent excessive current being sunk. Over Current Protection stops the load from sinking more current than its recommended limit and prevents the load from burn-out damage. Over Voltage Protection is used to limit the amount of voltage sink. If the OVP trips, the PEL-2000A Series load will stop sinking voltage. Over Power Protection is used when the input power exceeds the specifications of the load. When OPP is tripped, the power will cease to be sunk. Reverse Voltage Protection prevents reverse voltage damage to the PEL-2000A Series up to the specified rating. When Reverse Voltage Protection has been tripped, an alarm tone will sound until the reverse voltage is removed. Under Voltage Protection will turn off the load when the voltage drops below a set limit. The Go/NoGo function is available to monitor test results all the time. When a test result goes beyond a preset limit range, a “No Go” indication will be shown on the display and a “No Go” signal can be sent out through the D-SUB interface for external device control. This Go/NoGo function is available for CC mode, CV mode, and CR mode. Under “Program” mode, 12 programs, each containing 10 panel setup memories, can be edited to create work routines for repetitive tests. After a program has been executed, the results of all test steps, along with the Go/NoGo judgments, will be shown on the screen. For external control and system configuration, the PEL-2000A series has USB and RS-232 interfaces as standard and GPIB as an option. The LabView driver and Data Logging PC software are both supported for all the available interfaces. Each channel has an analog control/monitoring connector on the rear panel to externally turn a load on/off and to externally monitor load input current and voltage.

A. AUTOMATICALLY SEQUENCE FUNCTION
 1
The Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently, under the control of one clock. This is one of the most powerful features of the PEL-2000A Series as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed up to 25 s per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes.

The picture above is an example of a sequence used as a load profile for a single output switching power supply. A load profile is programmed to simulate the current draw of a power supply load. By using a current probe to acquire a current waveform, the PEL-2000A is able to evaluate the performance of a power supply based on the load sequence that is programmed. An oscilloscope is then used to display the result.

B. MULTIPLE OPERATING MODE
 2
C.C. ( Constant Current )
In Constant Current mode, a load unit will sink the amount of current programmed. Regardless of the voltage change, the current will stay the same. Two selectable ranges are available for constant current mode: High (HI) and low (LO) range. Low range has a higher resolution for high precision measurements. If the current exceeds the low range, high range must be used. The PEL-2000A Series offers the maximum rated power for the low measurement range. This unique feature enables high-resolution measurements at high voltage only if the load current doesn’t exceed the rated low range level. Both static and dynamic modes are available for CC operation. Static mode can be used for stability tests and Dynamic mode can be used to test transient load performance of a power supply. Go/NoGo is supported for both high and low ranges as well as Static and Dynamic modes.

The following are the basic specifications for the PEL-2000A series. For detailed specifications, please see the user manual.

PEL-2020A

Model

PEL-2020A (100Wx2)

RANGE

Low

High

CURRENT

0~2A

0~20A

VOLTAGE

1~80V

MIN.OP. VOLTAGE

0.4V at 2A

0.8V at 20A

0.2V at 1A

0.4V at 10A

CC OP. Range

0~2A

0~20A

CC Setting Range

0~2.04A

0~20.4A

CR OP. Range

0.075Ω~300Ω(100W/16V)

3.75Ω~15kΩ(100W/80V)

CR Setting Range

0.075Ω~300Ω(100W/16V)

3.75Ω~15kΩ(100W/80V)

CV+CC  OP. Range

1~80V

CV+CC Set. Range

0~81.6V

CP OP. Range

1~10W

1~100W

CP Setting Range

0~10.2W

0~102W

PEL-2030A

Model

PEL-2030A (30W/250W)

RANGE

Low

Low

High

CURRENT

0~5A

0~4A

0~40A

VOLTAGE

1~80V

MIN.OP. VOLTAGE

0.8V at 5A

0.4V at 4A

0.8V at 40A

0.4V at 2.5A

0.2V at 2A

0.4V at 20A

CC OP. Range

0~5A

0~4A

0~40A

CC Setting Range

0~5.1A

0~4.08A

0~40.8A

CR OP. Range

0.3Ω~1.2kΩ (30W/16V)
15Ω~60kΩ (30W/80V)

0.0375Ω~150Ω (250W/16V)
1.875Ω~7.5kΩ (250W/80V)

CR Setting Range

0.3Ω~1.2kΩ (30W/16V)
15Ω~60kΩ (30W/80V)

0.0375Ω~150Ω (250W/16V)1.875Ω~7.5kΩ (250W/80V)

CV+CC  OP. Range

1~80V

CV+CC Set. Range

0~81.6V

CP OP. Range

1~30W

1~25W

1~250W

CP Setting Range

0~30.6W

0~25.5W

0~255W

PEL-2040A/PEL-2041A

Model

PEL-2040A

PEL-2041A

RANGE

Low

High

Low

High

CURRENT

0~7A

0~70A

0~1A

0~10A

VOLTAGE

0~80V

0~500V

MIN.OP. VOLTAGE (Typ.)

0.4V at 7A

0.8V at 70A

0.4V at 1A

0.8V at 10A

0.2V at 3.5A

0.4V at 35A

0.2V at 0.5A

0.4V at 5A

CC OP. Range

0~7A

0~70A

0~1A

0~10A

CC Setting Range

0~7.14A

0~71.4A

0~1.02A

0~10.2A

CR OP. Range

0.025Ω~100Ω (350W/16V)
1.25Ω~5kΩ (350W/80V)

1.25Ω~5kΩ (350W/125V)
50Ω~200kΩ (350W/500V)

CR Setting Range

0.025Ω~100Ω (350W/16V)
1.25Ω~5k (350W/80V)

1.25Ω~5kΩ (350W/125V)
50Ω~200kΩ (350W/500V)

CV+CC  OP. Range

1~80V

2.5~500V

CV+CC Set. Range

0~81.6V

0~510V

CP OP. Range

1~35W

1~350W

1~35W

1~350W

CP Setting Range

0~35.7W

0~357W

0~35.7W

0~357W

Standard Accessories
Power Cable, CD ROM Contains PEL-2000A Series Electronic DC Load User Manual, Programming Manual and USB Driver
GTL-120 Load cables 2X red, 2X black (per load module)
GTL-121 Remote sense cables , 1X red, 1X black (per load module)

Optional Accessories
PEL-001 GPIB interface (Factory installed)
PEL-002 PEL-2000A Rack Mount kit (handle only)
GTL-232 RS-232C
GTL-246 USB
GTL-248 GPIB cable
GTL-249 Frame link

 Model Name  Description
PEL-2002A 2-Slot Programmable D.C. Electronic Load Mainframe
PEL-2004A 4-Slot Programmable D.C. Electronic Load Mainframe
PEL-2020A 200W, Dual Channel D.C. Electronic Load Module, (1~80V, 20A, 100W) x2
PEL-2030A 200W, Dual Channel D.C. Electronic Load Module, (1~80V, 5A, 30W) & (1~80V, 40A, 250W)
PEL-2040A 350W, Single Channel D.C. Electronic Load Module, (1~80V, 70A, 350W)
PEL-2041A 350W, Single Channel D.C. Electronic Load Module, (2.5~500V, 10A, 350W)